Turn MTT absorbance readings into per-cent viability against a control, with a mean and spread per group. For a concentration series it interpolates an IC50 from the points that bracket fifty per cent. Enter the blank so the dye-and-plate background is removed.

One group per line: a label (or a concentration, in series mode), then one or more absorbance replicates separated by commas. In series mode the row with concentration 0 is the control.

Control mean absorbance
IC50 (interpolated)

The IC50 is interpolated on a log scale between the two concentrations that bracket 50 per-cent viability. It is a reading off your points, not a fitted dose-response curve, and appears only when viability actually crosses 50 per cent within the range tested.

Viability per group is the blank-subtracted absorbance over the blank-subtracted control, as a per-cent. Replicates give a mean and a standard deviation. The blank is the medium-plus-reagent absorbance with no cells; subtracting it removes the background the dye and plate contribute.

Sign in — sign in to save this result

Formula

viability = (sample − blank) ÷ (control − blank) × 100

sample
the mean absorbance of the treated group
control
the untreated reference, taken as 100 per cent
blank
medium plus reagent, no cells; the background to subtract
IC50
interpolated on a log scale between the two doses that straddle 50 per cent

Worked example

A treated group against an untreated control

  • control mean 1.00
  • treated mean 0.525
  • blank 0.05
  1. Subtract the blank: 0.525 minus 0.05 is 0.475; 1.00 minus 0.05 is 0.95.
  2. Divide: 0.475 over 0.95 is 0.50.
  3. As a per cent: 50.

Answer 50 per-cent viability relative to the control

Common mistakes

  • Skipping the blank. Formazan sits on a background from medium, phenol red and the plate; without subtracting it, low-signal wells read too high.
  • Reading an IC50 off a curve that never reaches half. If viability stays above fifty across your range, there is no IC50 to interpolate; extend the doses rather than extrapolating.
  • Comparing plates read at different times or wavelengths. Formazan development and the read wavelength both shift absolute values; keep a control on every plate.

Frequently asked

Is the IC50 a fitted curve?

No. It is a straight interpolation between the two bracketing points on a log-dose scale. For a publication-grade value, fit a four-parameter model to all the points.

How many replicates?

Enough to see the spread; three technical wells per group is a common minimum, and the tool reports the standard deviation so you can judge it.

Can I use it for other tetrazolium assays?

Yes. MTS, XTT and WST share the same absorbance-to-viability arithmetic; only the reagent handling differs.